1
/
of
11
HGV Auto Electrics NI
HGV Auto 12v Pure Sine Inverter. 1Kw, 2Kw, 3Kw Options
HGV Auto 12v Pure Sine Inverter. 1Kw, 2Kw, 3Kw Options
Regular price
£145.00 GBP
Regular price
Sale price
£145.00 GBP
Quantity
Couldn't load pickup availability
HGV Auto 12v Pure Sine Inverter Range
1Kw, 2Kw, 3Kw Options
1000 Watt
- Rated Power 1000w
- Peak Power 2000w
- Input Voltage DC12v
- Output Voltage 220VAC/50hz
- Unload current less than 0.4a
- Output frequency 50Hz +0.5
- Output waveform Pure Sine
- Waveform Distortion THD3% Liner Load
- Max Efficiency 90%
- Input voltage range 10v - 15.5v
- Low voltage alarm 10.5
- Low voltage protection 10v
- Over voltage protection 15.5v
- Low voltage recover 12.3v
- Over voltage recover 14.8v
- Working temp -10 +50
- Dimensions 275x180x80
- Weight 2.5kg
- Warranty 2 Years
- Air Cooled
Protection functions and alarms
- Over voltage. Red light on and shut down
- Low voltage. Alarm sound, voltage reduce, red light on, shut down
- Over load. Red light on and shut down
- Over temp. Alarm sound, temp continues to rise, red light on, shut down
- Short circuit. Red light on
- Input reverse polarity. Fuse burn out.
2000 Watt
- Rated Power 2000w
- Peak Power 4000w
- Input Voltage DC12v
- Output Voltage 220VAC/50hz
- Unload current less than 0.9a
- Output frequency 50Hz +0.5
- Output waveform Pure Sine
- Waveform Distortion THD3% Liner Load
- Max Efficiency 90%
- Input voltage range 10v - 15.5v
- Low voltage alarm 10.5
- Low voltage protection 10v
- Over voltage protection 15.5v
- Low voltage recover 12.3v
- Over voltage recover 14.8v
- Working temp -10 +50
- Dimensions 355x205x95
- Weight 3.9kg
- Warranty 2 Years
- Air Cooled
Protection functions and alarms
- Over voltage. Red light on and shut down
- Low voltage. Alarm sound, voltage reduce, red light on, shut down
- Over load. Red light on and shut down
- Over temp. Alarm sound, temp continues to rise, red light on, shut down
- Short circuit. Red light on
- Input reverse polarity. Fuse burn out.
3000 Watt
- Rated Power 3000w
- Peak Power 6000w
- Input Voltage DC12v
- Output Voltage 220VAC/50hz
- Unload current less than 1a
- Output frequency 50Hz +0.5
- Output waveform Pure Sine
- Waveform Distortion THD3% Liner Load
- Max Efficiency 90%
- Input voltage range 10v - 15.5v
- Low voltage alarm 10.5
- Low voltage protection 10v
- Over voltage protection 15.5v
- Low voltage recover 12.3v
- Over voltage recover 14.8v
- Working temp -10 +50
- Dimensions 415x205x95
- Weight 5kg
- Warranty 2 Years
- Air Cooled
Protection functions and alarms
- Over voltage. Red light on and shut down
- Low voltage. Alarm sound, voltage reduce, red light on, shut down
- Over load. Red light on and shut down
- Over temp. Alarm sound, temp continues to rise, red light on, shut down
- Short circuit. Red light on
- Input reverse polarity. Fuse burn out.
Share